SC120
• Outer diameter: max. 120 mm • Inner diameter: max. 70 mm • Fieldbusses • Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6) • Flexibily configurably interfacesSC120
• Outer diameter: max. 120 mm
• Inner diameter: max. 70 mm
• Fieldbusses
• Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6)
• Flexibily configurably interfaces- Categories: SC120
- Tags: Food Processing Industry Medical equipment manufacturers metal Packaging Industry Pharma Renewable energy Robotics
-

SC168
• Outer diameter: max. 168 mm • Fieldbusses • Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6) • Offshore version possible • Flexibily configurable interfacesSC168
• Outer diameter: max. 168 mm
• Fieldbusses
• Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6)
• Offshore version possible
• Flexibily configurable interfaces- Categories: SC168
- Tags: Food Processing Industry Medical equipment manufacturers metal Packaging Industry Pharma Renewable energy Robotics
-

SC2X0
• Outer diameter: max. 290 mm • Inner diameter: max. 180 mm • Fieldbusses • Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6) • Flexibily configurable interfacesSC2X0
• Outer diameter: max. 290 mm
• Inner diameter: max. 180 mm
• Fieldbusses
• Fast Ethernet (certified to 100-BaseT Cat.5e & Cat.6)
• Flexibily configurable interfaces- Categories: SC2X0
- Tags: Packaging Industry
-

SC3X0
• Outer diameter: max. 390 mm • Inner diameter: max. 190 mm • Fieldbusses • Fast Ethernet (certified to 100-BaseT CAT5e & Cat6) • Flexibily configurable interfacesSC3X0
• Outer diameter: max. 390 mm
• Inner diameter: max. 190 mm
• Fieldbusses
• Fast Ethernet (certified to 100-BaseT CAT5e & Cat6)
• Flexibily configurable interfaces- Categories: SC3X0
- Tags: Packaging Industry
-

SDX
• Outer diameter: max. 300 mm • Inner diameter: max. 170 mm • Special design possible • Combination with electronic components possible • FieldbussesSDX
• Outer diameter: max. 300 mm
• Inner diameter: max. 170 mm
• Special design possible
• Combination with electronic components possible
• Fieldbusses- Categories: SDX
- Tags: Robotics
-

SG10
• Compact design • Universally applicable thanks to standardized interfaces • Easy mounting • Measurement lengths up to max. 2000 mm • Potentiometer, voltage, power output or incremental encoder • Housing made of reinforced plasticSG10
• Compact design
• Universally applicable thanks to standardized interfaces
• Easy mounting
• Measurement lengths up to max. 2000 mm
• Potentiometer, voltage, power output or incremental encoder
• Housing made of reinforced plastic- Categories: SG10
- Tags:
-

SG20
• Compact design • Universally applicable thanks to standardized interfaces • Easy mounting • Measurement lengths up to max. 2000 mm • Potentiometer, voltage or power output • Robust zinc die-cast housingSG20
• Compact design
• Universally applicable thanks to standardized interfaces
• Easy mounting
• Measurement lengths up to max. 2000 mm
• Potentiometer, voltage or power output
• Robust zinc die-cast housing- Categories: SG20
- Tags:
-

SG30
• Compact • Robust design • Variable mounting options • Measuring lengths up to 3000 mm • Potentiometer, voltage or power output • Housing made of zinc die-cast and plastic • Lockable ventilation holes against condensation • High tightness at the rope outlet M12 plug connectionSG30
• Compact
• Robust design
• Variable mounting options
• Measuring lengths up to 3000 mm
• Potentiometer, voltage or power output
• Housing made of zinc die-cast and plastic
• Lockable ventilation holes against condensation
• High tightness at the rope outlet M12 plug connection- Categories: SG30
- Tags:
-

SG31
• Robust design • Measuring lengths up to 3000 mm • Wire-actuated encoder for rotary encoder with 58 mm servo-flange • Variable mounting options • Lockable ventilation holes against condensation • Very robust measuring rope (stainless steel) • High tightness at the rope outlet Also available as a safety version in combination with WV58MR rotary encoderSG31
• Robust design
• Measuring lengths up to 3000 mm
• Wire-actuated encoder for rotary encoder with 58 mm servo-flange
• Variable mounting options
• Lockable ventilation holes against condensation
• Very robust measuring rope (stainless steel)
• High tightness at the rope outlet Also available as a safety version in combination with WV58MR rotary encoder- Categories: SG31
- Tags:
-

SGH10
•Measuring range 0 … 1000 mm (39.37 inches) •Absolute measuring system •CANopen interface, analog: Current and voltage •Operating voltage 9 ... 32 VDC •Pressure-resistant up to 350 bar, pressure peaks up to 450 bar •High degree of flexibility, adjustable to all measuring lengths thanks to teach-in •High electro-magnetic compatibility •High shock and vibration resistance With PURE.MOBILE technologySGH10
•Measuring range 0 … 1000 mm (39.37 inches)
•Absolute measuring system
•CANopen interface, analog: Current and voltage
•Operating voltage 9 … 32 VDC
•Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
•High degree of flexibility, adjustable to all measuring lengths thanks to teach-in
•High electro-magnetic compatibility
•High shock and vibration resistance
With PURE.MOBILE technology- Categories: SGH10
- Tags:
-

SGH25
•Measuring range 0 … 2500 mm (98.42 inches) •Absolute measuring system •Pressure-resistant up to 350 bar, pressure peaks up to 450 bar •High degree of flexibility, adjustable to all measuring lengths thanks to teach-in •Redundant interfaces (CAT3) available •Safety version usable up to Performace Level d •Analog, CANopen, SAE J1939, CANopen Safety interfacesSGH25
•Measuring range 0 … 2500 mm (98.42 inches)
•Absolute measuring system
•Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
•High degree of flexibility, adjustable to all measuring lengths thanks to teach-in
•Redundant interfaces (CAT3) available
•Safety version usable up to Performace Level d
•Analog, CANopen, SAE J1939, CANopen Safety interfaces- Categories: SGH25
- Tags:
-

SGH50
•Measuring range 0 … 5000 mm (196.85 inches) •Absolute measuring system •Pressure-resistant up to 350 bar, pressure peaks up to 450 bar •High degree of flexibility, adjustable to all measuring lengths thanks to teach-in Redundant interfaces (CAT3) available •Safety version usable up to Performace Level d •Analog, CANopen, SAE J1939, CANopen Safety interfaces With PURE.MOBILE technologySGH50
•Measuring range 0 … 5000 mm (196.85 inches)
•Absolute measuring system
•Pressure-resistant up to 350 bar, pressure peaks up to 450 bar
•High degree of flexibility, adjustable to all measuring lengths thanks to teach-in
Redundant interfaces (CAT3) available
•Safety version usable up to Performace Level d
•Analog, CANopen, SAE J1939, CANopen Safety interfaces
With PURE.MOBILE technology- Categories: SGH50